What is HTM 01-05 and why is it important?

HTM 01-05 is the Department of Health guidance on decontamination in primary care dental practices in England. It was first published in 2009, and the current version is the 2013 edition, which is still in force today. Practices in Wales and Scotland follow their own versions, WHTM 01-05 and SHTM 01-05.

Are you the IPC lead in your practice?

Build the knowledge to lead infection prevention and control with confidence. Our accredited IPC Lead courses are studied online, at your own pace.

Level 2 IPC LeadLevel 2 and 3 IPC Lead

The aims and objectives of HTM 01-05 are:

  • Recognition of the difference between cleaning, disinfection and sterilisation.
  • Implementation of Practice procedures and policies.
  • Understanding of maintenance, testing, storage and disposal.
  • Understanding the importance of Personal Protective Equipment.
  • Operating safely and practically within the law and current national guidance.
  • Recognition and minimisation of cross-infection.

Refresher on the basics

Cross-Infection

Cross infection is the term given to harmful micro-organisms being transmitted from one person to another due to poor or no protection. For example; using the same set of instruments on more than one patient is cross-infection. Cross-infection can occur in a number of ways and take a number of different routes. Recognised routes are;

  • Direct and indirect contact (for example via hands, surfaces or instruments)
  • Ingestion
  • Aerosol and droplets
  • Inoculation (for example sharps injuries)

It is very important that we prevent and minimise cross-infection as much as possible by:

  • Wearing and asking the patient to wear PPE.
  • Disinfecting worktops and equipment.
  • Cleaning and sterilising instruments correctly.

Cleaning

Cleaning is the first stage of decontamination. It removes blood, saliva and other debris, and instruments must be visibly clean before they are sterilised. Instruments can be cleaned in a washer-disinfector, in an ultrasonic bath or by hand. An ultrasonic bath uses sound waves in a cleaning solution to loosen debris. Only use a solution that the ultrasonic manufacturer recommends, even if it is described as disinfecting, and instruments must always go on to be sterilised afterwards.

Disinfection

Disinfection involves the use of a disinfectant spray or wipes which can be used on all surfaces or equipment that can’t be sterilised. Disinfection will kill micro-organisms but not all bacterial spores. Disinfection does however reduce bacteria to low levels which are non-harmful. Disinfection is less effective than sterilisation but unfortunately we cannot put the dental chair in the autoclave!

Sterilisation

Sterilisation is the process intended to destroy or remove all living organisms from an object. Unlike disinfection, sterilisation completely kills all micro-organisms when done correctly. Instruments need to be cleaned and sterilised after use and the most common way is by using an autoclave.

How the decontamination cycle fits together

Every reusable instrument goes through the same journey after it has been used. It is carried from the surgery to the decontamination area in a lidded container, then cleaned until no blood or debris remains. Each instrument is checked under an illuminated magnifier, and anything still dirty is cleaned again, while damaged instruments are taken out of use. The instruments are then sterilised in the autoclave. Instruments for a vacuum (type B or S) autoclave are wrapped first, while those from a non-vacuum (type N) autoclave are wrapped afterwards if they are to be stored. Finally, they are stored somewhere clean and dry until they are needed. If any one of these steps is missed or rushed, the steps after it cannot make the instrument safe.

HTM 01-05

HTM 01-05 sets two levels. The essential quality requirements are the minimum every practice must meet. Best practice is the higher standard practices should be working towards, which includes cleaning instruments in a washer-disinfector and having a separate decontamination room. Below are the main requirements.

Essential quality requirements and best practice

Essential quality requirements (the minimum)

Best practice (the standard to work towards)

Cleaning

Instruments cleaned in a washer-disinfector, an ultrasonic bath or by hand, using a validated process. Manual cleaning needs a written protocol. Instruments must be visibly clean before sterilising.

Cleaning in a validated washer-disinfector. Manual cleaning only for items the manufacturer says cannot be machine cleaned, or while the washer-disinfector is out of action.

Sterilising

A validated steam steriliser (autoclave).

The same.

Where decontamination happens

A designated decontamination area, which can be within or next to the surgery.

A separate room, or rooms, away from the surgery, keeping dirty and clean work apart. Used only for decontamination, with access limited to the staff doing it.

Storing instruments

Stored so they are protected from contamination, within the storage time limits.

A dedicated storage area clearly separate from the surgery, usually in the clean side of the decontamination room.

Audit

Every six months, ideally using the Infection Prevention Society audit tool.

The same.

Planning

A written plan showing how the practice will move towards best practice.

Best practice reached.

Guidelines with regards to:

Protocol

  • A detailed plan for "best practice" must be written and explain what is going to be done in order to move forward.
  • An appointed person should be responsible for infection control and decontamination.
  • An infection-control policy should be in place that meets the essential requirements. It should be reviewed at least every two years, and every member of the team needs to read and follow it. Many practices ask each team member to sign to confirm they have read it.
  • A validated cleaning cycle should be in place and a protocol made explaining this.
  • Audits should be carried out at least every six months, using the recommended Infection Prevention Society audit tool, and kept for at least 2 years.
  • Autoclaves should be tested daily and results recorded. This includes an automatic control test and, for vacuum autoclaves, a steam penetration test. A written protocol should be in place.
  • Dental unit water lines (DUWLs) should be flushed for at least two minutes at the start and end of each day and after long breaks, and for 20 to 30 seconds between patients. They should be disinfected periodically following the manufacturer’s instructions. Self-contained water bottles should use distilled or reverse osmosis water. Every practice needs a Legionella risk assessment and a written scheme for controlling the risks. A written protocol should be in place.
  • All staff should be up to date with immunisations and be able to provide evidence of this, including hepatitis B immunisation for staff carrying out decontamination.
  • Every Dental Practice must have an Accident Report book, and a record should be kept of all sharps injuries.
  • Every member of staff should have a Personal File which should include a signed copy of the infection-control policy, details of any accidents reported, copies of immunisations, training records and risk assessments.
  • A written policy detailing a validation/checklist for Manual Cleaning should be in place. This should include checking the use of the correct detergent, a mercury-free thermometer to check the water stays at 45°C or lower and also an illuminated magnifier to inspect the instruments.
  • A written policy detailing a validation/checklist for PPE should be in place. This should include checking the use of safety glasses, gloves, face masks, face visors and disposable aprons.
  • A written policy detailing a validation/checklist for the Ultrasonic Bath should be in place. This should include daily checks (cleaning the strainers and filters, draining at the end of the day and checking instruments are visibly clean), weekly checks (the safety checks and a protein residue test) and quarterly tests, unless the manufacturer says otherwise. Lastly, checking the use of the correct detergent and making sure the bath has a lid, which should be closed while it is running.

Cleaning instruments

  • There should be dedicated hand-washing facilities in addition to two separate sinks, one for washing and one for rinsing.
  • Instruments must be transported from surgery to the decontamination area in rigid, durable, leak-proof containers with lids on. There must be clean and dirty containers.
  • Manual cleaning must be done wearing heavy duty gloves and using a long-handled brush with soft plastic bristles. Single-use brushes are preferred. Reusable brushes should be washed in hot water and detergent after each use, stored dry and head up, and replaced as the manufacturer recommends or sooner if worn. Wire brushes should not be used. Instruments must be held with the sharp end facing away and they should be fully immersed in detergent solution at 45°C or lower. PPE should be worn in order to prevent splatter. Instruments should be inspected with an illuminated magnifier after cleaning and before sterilising.
  • Ultrasonic baths must be filled with the detergent solution made up to the manufacturer’s instructions. Instruments should go in the basket, not on the floor of the bath, and the basket should not be overloaded.

Infection control in the surgery

  • The aspirator and spittoon should be cleaned between every patient. The suction system should be cleaned with a non-foaming cleaner as the manufacturer recommends.
  • Impressions need to be rinsed under running water until visibly clean, then disinfected following the manufacturer’s instructions and rinsed again. If they are sent to a laboratory, they should be labelled to show they have been decontaminated.
  • Uniforms must not be worn outside the practice or in any eating areas. A freshly laundered uniform should be worn every day, changed sooner if visibly contaminated, and washed at the hottest temperature suitable for the fabric.
  • Hands should be washed with liquid soap, rubbing all surfaces of the hands for about 15 seconds, and dried with disposable paper towels. All jewellery must be removed (a plain wedding ring is allowed, although removing it is preferable), nails should be kept short and clean, and nail varnish or false nails must not be worn. Cuts and abrasions need to be covered up. Hands need to be washed using a liquid soap from a wall-mounted dispenser with disposable cartridges at the beginning and end of each session. Alcohol hand rub can be used instead of washing when hands are visibly clean, but it must not be used on gloves. Alcohol wipes should be avoided. If hand cream is used, it needs to be water based and come from a wall-mounted dispenser rather than a communal tub.

Sterilisation

  • Every practice must have a validated steam steriliser.
  • Wrapped instruments can be stored for up to one year. With a vacuum (type B or S) autoclave they are wrapped before sterilising; with a non-vacuum (type N) autoclave they are wrapped after sterilising. Unwrapped instruments can be stored for one day in the surgery, or for one week in a non-clinical area, kept dry and covered, for example in drawer inserts, never on open worktops. The date of sterilisation, expiry date and signature of the person responsible for the sterilisation needs to be documented.
  • Autoclaves must not be overloaded and should be loaded following the manufacturer’s instructions.
  • Best practice is a separate decontamination room, or rooms, away from the surgery. Until then, a clearly designated decontamination area is acceptable. Either way, there should be a hand basin plus separate sinks for washing and rinsing, and clearly labelled clean and dirty areas. There should be an air flow maintained and no portable fans. There should be no clutter. Everybody who uses this area must be fully trained on the procedure that needs to be followed.
  • Cleaning instruments in a validated washer-disinfector is part of best practice. Manual cleaning should then only be used for items the manufacturer says cannot go in it.

Disposal

  • Every Dental Practice should have a "single use" policy for items such as prophy brushes and cups, matrix bands, saliva ejectors, aspirator tips and three-in-one tips. Endodontic reamers and files should be treated as single use, or single patient use, whatever the manufacturer says. Single-use items must never be reprocessed, and anyone who does so takes on full responsibility for their safety.
  • Gloves and face masks are single use and must be replaced with every patient, then disposed of as clinical waste.
  • Ensure that amalgam waste is not mixed with any other type of waste.
  • Keep records of hazardous waste, including consignment notes, over a minimum of 3 years.

For more information on HTM 01-05 you can download the 2013 edition from NHS England.

Further reading

Are you the IPC lead in your practice?

Build the knowledge to lead infection prevention and control with confidence. Our accredited IPC Lead courses are studied online, at your own pace.

Level 2 IPC LeadLevel 2 and 3 IPC Lead

Written by Dental Nurse Network. Last updated November 2026.

Get in Touch With Our Friendly Team Today

Quick Enquiry

Please type your full name.
Invalid email address.
Invalid Input
Invalid Input
Join our community to receive career advice, inspiration and access free CPD and other opportunities
Contact
Dental Nurse Network,
20-22 Wenlock Road, London,
United Kingdom, N1 7GU
Website Links